GMP

Identify adulteration of cow milk by addition of bovine whey in less than 30 minutes.

 

Do you need to verify that your milk has not been adulterated with whey?
Do you need your milk to be close to milking to ensure the stability of your products?

[button size=»small» icon=»fa-phone» target=»_self» hover_type=»default» text_align=»center» text=»CONTACT US» background_color=»#1e73be» border_color=»#1e73be» hover_background_color=»#fc634a» hover_border_color=»#fc634a» link=»#seccion-contacto»]

HOW DOES IT HELP YOU?

 

With The GMP kit you can easily to detect the presence of GMP in cow milk in 30 minutes. GMP is an indicator of whey addition to milk and psychotropic flora growth.

MATRIX
[icon_text box_type=»normal» icon_type=»normal» icon_position=»top» icon_size=»fa-2x» use_custom_icon_size=»no» title_tag=»h6″ separator=»no» title=»COW RAW & POWDER MILK» image=»2470″]
APPLICATIONS AND USERS
[icon_text box_type=»normal» icon_type=»normal» icon_position=»top» icon_size=»fa-2x» use_custom_icon_size=»no» title_tag=»h6″ separator=»no» title=»LABORATORY» image=»2539″]
[icon_text box_type=»normal» icon_type=»normal» icon_position=»top» icon_size=»fa-2x» use_custom_icon_size=»no» title_tag=»h6″ separator=»no» title=»PLANT» image=»2474″]
[icon_text box_type=»normal» icon_type=»normal» icon_position=»top» icon_size=»fa-2x» use_custom_icon_size=»no» title_tag=»h6″ separator=»no» title=»INDUSTRY» image=»3260″]

ASSAY PROCEDURE

[qode_elements_holder number_of_columns=»two_columns» columns_proportion=»25_75″][qode_elements_holder_item advanced_animations=»no» background_color=»#f5f6f6″ item_padding=»10px 20px 10px 15px» item_padding_1280_1440=»0px 0px 0px 0px» item_padding_1024_1280=»0px 0px 0px 0px» item_padding_768_1024=»0px 0px 0px 0px»]

1. Mixt:

Sample and solution.

2. Wait:

5 min.

3. Resultados:

Visual reading

[/qode_elements_holder_item][/qode_elements_holder]
[qode_elements_holder number_of_columns=»two_columns» columns_proportion=»25_75″][qode_elements_holder_item advanced_animations=»no» item_padding=»0px 15px 0px 0px» item_padding_1280_1440=»0px 15px 0px 0px» item_padding_1024_1280=»0px 15px 0px 0px» item_padding_768_1024=»0px 15px 0px 0px» item_padding_600_768=»0px 0px 15px 0px» item_padding_480_600=»0px 0px 15px 0px» item_padding_480=»0px 0px 15px 0px»][qode_video_box video_link=»https://www.youtube.com/watch?v=ND4RlbEaetM» video_image=»1651″]

Nombre del video

[/qode_elements_holder_item][qode_elements_holder_item advanced_animations=»no» background_color=»#f5f6f6″ item_padding=»10px 20px 10px 15px» item_padding_1280_1440=»0px 0px 0px 0px» item_padding_1024_1280=»0px 0px 0px 0px» item_padding_768_1024=»0px 0px 0px 0px»]

1. Dilución de la muestra:

Aplicar muestra/patrón. Incubación.

2. Conjugado:

Incubación

3. Resultados:

Lectura fotométrica a 450nm

[/qode_elements_holder_item][/qode_elements_holder]

TEST PRINCIPLE

Rapid immunochromatographic test based on the detection of thermo-resistant regions of bovine b-lactoglobulin using specific antibodies.

TECHNICAL DATA

  • Limit of detection:  15-30 µg/ml of GMP. Equivalent to 1-2% of whey.
  • Assay time: 30 minutes
  • Results: Visual reading

 

Validations:

Internal validation following the AOAC guidelines:
Appendix F: Guidelines for Standard Method Performance Requirements. Official Methods of Analysis (2016), AOAC INTERNATIONAL, Rockville, MD, USA (www.eoma.aoac.org)
Appendix N: ISPAM Guidelines for Validation of Qualitative Binary Chemistry Methods. AOAC (2013) (www.eoma.aoac.org) Wehling P, LaBudde RA, Brunelle SL, Nelson MT, 2011. Probability of Detection (POD) as a statistical model for the validation of qualitative methods. J AOAC Int 2011, 94:335-347.

Related articles

[latest_post type=»boxes» number_of_colums=»4″ number_of_rows=»1″ text_from_edge=»yes» order_by=»date» order=»DESC» title_tag=»h4″ display_category=»0″ display_time=»1″ display_comments=»0″ display_like=»0″ display_share=»0″ text_length=»0″ category=»adulteraciones»]
Scroll al inicio